6.3 Push the mixing rod all the way to the bottom of the
cartridge and with a clockwise motion begin mixing 60 complete strokes. In and out
constitutes one complete stroke,
6.4 Push mixing rod all the way in, then unscrew the mixing
rod remove from cartridge and discard. With a quick motion, place the cartridge unto
the threaded injection fitting of the SV Closure and screw tightly into place. |
|
6.5 Disengage the thumb screw from the threads of the injection
handle. Using a fas and steady motion, inject the compound into the Sv closure until the
compound flows bubble free from the vent holes. Seal vent holes with vent plugs and
tape over plugs to secure them in place.
6.6 Engage the thumb screw into the threads of the injection
handle. Continue injecting compound at a rate of 3 minutes per cartridge until the required
amount of compound has been injected or until a good back preessure is attained.
Re move the cartridge from the injection fitting and make certain that the ball in the
fitting is at the top in the closed position. If the ball is not in a closed position,
add an additional cartridge. |